Behöver du en bruksanvisning för din Steinel IS 130-2 Rörelsedetektor? Nedan kan du se och ladda ner PDF-bruksanvisningen gratis på svenska. Den här produkten har för närvarande 0 vanliga frågor, 2 kommentarer och har 5 röster med ett genomsnittligt produktbetyg på 20/100. Om det här inte är bruksanvisningen du vill ha, vänligen kontakta oss.

Är produkten defekt och erbjuder bruksanvisningen ingen lösning? Gå till ett Repair Café för gratis reparationstjänster.

Bruksanvisning

Loading…

321
110018691 02/2012_C
IS 130-2
i
Principle
Movement triggers lights, alarms and many other devices - for your convenience and safety. The integrated
pyroelectric infrared detector senses the invisible heat radiated from moving objects (people, animals, etc.).
The heat detected in this way is converted electronically into a signal that activates the load connected. Heat
radiation is not detected through obstacles, such as walls or glass, and will therefore not activate the light.
Safety warnings
During installation, the electrical wiring being connected must be dead. Therefore, switch off the power first
and use a voltage tester to check that the power supply is disconnected.
Installing this unit involves work on the mains voltage supply. This must therefore be carried out
in accordance with applicable national wiring regulations and electrical operating conditions.
(
D
- VDE 0100,
A
-ÖVE-ÖNORM E8001-1,
-SEV 1000)
Only use genuine replacement parts.
Do not dismantle the unit yourself. It must only be repaired by a specialist workshop.
Installation
L = live conductor (usually black or brown)
Connection with concealed wiring
N = neutral conductor (usually blue)
Connection with exposed wiring
PE = any protective earth conductor (green/yellow)
Attention: Loop the protective-earth conductor through if necessary. A mains power switch for turning the unit
ON and OFF may of course be installed in the mains supply lead. Important: Reversing the connections may
result in damage to the unit. Please note that the circuit must be protected by a 10 A circuit breaker.
Minimum installation height: 1.70 m.
Fluorescent lamps, low-energy bulbs, LED lights with electronic ballast (total capacity of all connected
ballasts below the value specified) operating on 230 V AC.
Function
Twilight setting (factory setting: daylight operation at 2000 lux):
The sensor's response threshold can be infinitely varied from 2 – 2000 lux.
Control dial set to = daylight operation at approx. 2000 lux.
Control dial set to = night-time operation at approx. 2 lux.
To adjust the detection zone in daylight, the control dial must be set to (daylight operation).
Time setting (factory setting: 8 sec.): Light 'ON' time can be set from 8 secs. to 35 mins.
Control dial set to – = shortest time (8 sec.)
Control dial set to + = longest time (35 min.)
When setting the detection zone, it is recommended to select the shortest time –.
Adjust detection zone at swivel mount
Reach 2 – 12 m, by tilting sensor lens through 90°.
Using adhesive shrouds, e.g. to mask out paths or neighbouring properties.
Important: The most reliable way of detecting motion is to install the SensorLight with the sensor aimed across
the direction in which a person would walk and by ensuring that no obstacles (such as trees and walls, for
example) obstruct the line of sensor vision. Reach is limited when walking directly towards the light.
Troubleshooting (Fault / Cause
Remedy
)
No power / Fuse faulty, not switched on
new fuse, turn power switch ON, check lead with voltage tester.
Will not switch ON / Surroundings still too bright
wait until response threshold is reached or adjust setting
/
Bulb faulty
change bulb /
Power switch OFF
switch on /
Detection zone not properly targeted
readjust.
Will not switch OFF / Permanent movement in the detection zone
adjust detection zone
. Keeps switching
ON/OFF / There is a light in the detection zone
change detection zone, increase distance
. Switches ON
when unwanted / Detecting cars on the road, for example
change detection zone, tilt sensor down.
Reach changing / Differing ambient temperatures
at low temperatures, shorten reach by tilting sensor
down; at high temperatures, tilt sensor up.
Declaration of conformity
This product complies with Low Voltage Directive 2006/95/EC, EMC Directive 2004/108/EC and RoHS Directive
2002/95/EC.
Functional warranty
This STEINEL product has been manufactured with great care, tested for proper operation and safety in accordance
with applicable regulations and then subjected to random sample inspection. STEINEL guarantees that it is perfect
condition and proper working order. The warranty period is 36 months, starting from the date of sale to the con-
sumer. We will remedy defects caused by material flaws or manufacturing faults. The warranty will be met by
repair or replacement of defective parts at our own discretion. The warranty does not cover damage to wear parts,
nor does it cover damage or defects caused by improper treatment, maintenance or the use on non-genuine parts.
Further consequential damage to other objects shall be excluded. The warranty will only be honoured if the product
is sent to the appropriate Service Centre fully assembled and well packed with a brief description of the fault,
receipt or invoice (date of purchase and dealer's stamp). Service: Our Customer Service Department will repair
faults not covered by warranty or after the warranty period. Please send the product well packed to your
nearest Service Centre.
ENGLISH
GB
18
7
9
8
10
5
6
10
11
Ladda ner bruksanvisning i Svenska (PDF, 9.47 MB)
(Tänk på miljön och skriv endast ut denna bruksanvisning om det verkligen är nödvändigt)

Loading…

Betyg

Berätta vad du tycker om Steinel IS 130-2 Rörelsedetektor genom att betygsätta den. Vill du dela med dig av dina åsikter om denna produkt eller ställa en fråga? Lämna en kommentar nederst på sidan.
Är du nöjd med Steinel IS 130-2 Rörelsedetektor?
Ja Nej
20%
80%
5 röster

Delta i konversationen om denna produkt

Här kan du dela vad du tycker om Steinel IS 130-2 Rörelsedetektor. Om du har en fråga, läs först noggrant igenom manualen. Att begära en manual kan göras genom att använda vårt kontaktformulär.

Jean Demorieux 23-01-2021
Jag har precis anslutit IS 130-2-sensorn till 220 v-nätverket och till LED-projektorn, respektera instruktionerna i monteringsanvisningarna och se till att nätverkskabeln ansluten i position L verkligen var den för fasen (226 v i förhållande till jorden) Efter anslutning till elnätet slås inte projektorn på !! vilken diagnos kan härledas (potentiometerns position på månen) och medianpositionen för ljusets varaktighet

svara | Detta hjälpte (8) (Översatt av Google)
Tacheau 03-09-2021
Hej, jag har bara tre söner som kommer ut från min vägg. En svart, en blå och en jordgulgrön. Jämfört med din produkt saknar jag en tråd för att driva det lila. Kan du berätta mer. hjärtligt

svara | Detta hjälpte (7) (Översatt av Google)

Mer om denna bruksanvisning

Vi förstår att det är trevligt att ha en pappersbruksanvisning för din Steinel IS 130-2 Rörelsedetektor. Du kan alltid ladda ner bruksanvisningen från vår hemsida och skriva ut den själv. Om du vill ha en originalbruksanvisning rekommenderar vi att du kontaktar Steinel. De kanske kan tillhandahålla en originalbruksanvisning. Letar du efter bruksanvisningen för din Steinel IS 130-2 Rörelsedetektor på ett annat språk? Välj ditt föredragna språk på vår hemsida och sök efter modellnumret för att se om vi har det tillgängligt.

Specifikationer

Märke Steinel
Modell IS 130-2
Kategori Rörelsedetektorer
Filtyp PDF
Filstorlek 9.47 MB

Alla bruksanvisningar för Steinel Rörelsedetektorer
Fler bruksanvisningar för Rörelsedetektorer

Bruksanvisning Steinel IS 130-2 Rörelsedetektor

Relaterade produkter

Relaterade kategorier