Button Functions
RT520 / RT520RF Thermostat RXRT520 Receiver
1 2 3 4 5 6
7
8
9
10
1. MENU - enter the menu options, press and
hold for 3 sec to return to main screen or to
deactivate Boost Mode
2. SELECT - conrm changes and enter menus
3. DOWN - decrease the temperature and
move through the menus
4. UP - increase the temperature and move
through menus
5. BOOST - activate Boost Mode
6. MANUAL - activate / deactivate Manual Mode
7. ON - When in Manual Mode, ON will
turn the boiler on.
8. OFF - When in Manual Mode, OFF
will turn the boiler o.
9. AUTO - Receiver operates in automatic
mode according to the thermostat.
10. MANUAL - Receiver output is
controlled by the On/O slide switch.
SALUS Controls plc
SALUS House
Dodworth Business Park South, Whinby Road, Dodworth,
Barnsley S75 3SP, UK.
T: +44 (0) 1226 323961
SALUS Controls is a member of the Computime Group.
Maintaining a policy of continuous product development SALUS Controls plc reserve
the right to change specification, design and materials of products listed in this brochure
without prior notice.
www.salus-tech.com
Issue Date: September 2018
V009
For PDF Installation guide please go to www.salus-manuals.com
1 32
15
Introduction
The RT520 and RT520RF are the latest additions to SALUS’ tried and tested RT range of thermostat
heating controls. With a new on-board load compensation feature, they oer the most cost eective
fully compliant Boiler Plus solution on the market providing the homeowner with optimum eciency
and maximum heating control comfort. Available in both wired and wireless RF versions, the new RT520
series include all the features of the previous RT series with a larger more intuitive LCD display and a
handy new suite of additional operational and eciency functions.
Before use please read this manual carefully.
Product Compliance
Safety Information
This product complies with the essential requirements and other relevant provisions of the following EU Directives:
EMC 2014/30/EU, LVD 2014/35/EU, RED 2014/53/EU and RoHS 2011/65/EU. Full text of the EU Declaration of
Conformity is available on www.saluslegal.com
Use in accordance to national and EU regulations. Use the device as intended, keeping it in dry condition.
Product for indoor use only. Installation must be carried out by a qualied person in accordance to national
and EU regulations.
868.0-868.6MHz; <13dBm
Technical Specication
RT520 Thermostat RT520TX Thermostat
Thermostat supply 2 x AA alkaline batteries 2 x AA alkaline batteries
Thermostat rating max 3 (1) A -
OpenTherm terminals A / B -
Outputs
Voltage free
NC / NO / COM
terminals
-
Temperature range 5°C – 33.5°C 5°C – 33.5°C
Temperature accuracy 0.1°C or 0.5°C 0.1°C or 0.5°C
ErP control class V V
Radio frequency - 868 MHz
Dimension [mm] 118 x 95 x 26 [mm] 118 x 95 x 26 [mm]
RXRT520 Receiver
Receiver supply 230 V AC
Receiver rating max 16 (5) A
OpenTherm terminals A / B
Outputs Voltage free NO / COM terminals
Radio frequency 868 MHz
Dimension [mm] 96 x 96 x 26 [mm]
LCD Icon Description
1
5
3A
7
2
6
3B
8
4
9
11
14
16
10
13
12
15
17
RT520 Thermostat Terminals Description
RXRT520 Receiver Terminals Description
Terminal Description
B / A OpenTherm Communication Wire
NC Switched Live OFF
NO Switched Live ON
COM Common Terminal
Terminal Description
B / A OpenTherm Communication Wire
NO Switch Terminal
COM Common Switch Terminal
L; N Supply (230 V AC)
RT520 Wiring Diagram
OpenTherm - Hot Water
TPI, SPAN
TPI, SPAN
OPENTHERM
OPENTHERM
RT520TX Wiring Diagram
OpenTherm Power Up and Conguration
RT520TX
Thermostat
COM
NO
NC
RT520
Thermostat
B A
RT520
Thermostat
L
L
NO
N
N
COM
RXRT520
Receiver
AC 230 V
RT520TX
Thermostat
L
L
BA
N
N
RXRT520
Receiver
AC 230 V
RT520TX
Thermostat
COM
NO
NC
RT520
Thermostat
B A
RT520
Thermostat
L
L
NO
N
N
COM
RXRT520
Receiver
AC 230 V
RT520TX
Thermostat
L
L
BA
N
N
RXRT520
Receiver
AC 230 V
RT520TX
Thermostat
COM
NO
NC
RT520
Thermostat
B A
RT520
Thermostat
L
L
NO
N
N
COM
RXRT520
Receiver
AC 230 V
RT520TX
Thermostat
L
L
BA
N
N
RXRT520
Receiver
AC 230 V
RT520TX
Thermostat
COM
NO
NC
RT520
Thermostat
B A
RT520
Thermostat
L
L
NO
N
N
COM
RXRT520
Receiver
AC 230 V
RT520TX
Thermostat
L
L
BA
N
N
RXRT520
Receiver
AC 230 V
Text Bar
AM / PM
Day of the week (numeric)
Holiday Mode On
Temperature Unit
Frost Protection Mode On
Day of the week (alphabetic)
Manual Mode On
Clock
Heating Mode On
Wireless connection with the receiver
Program number
Program indicator
Low battery status
Temperature measured / set
Service Mode On
Settings
Boost function
Always ensure the AC mains power is switched off before installing or working on any
components (this includes replacing the batteries). Use only AA 1.5 V alkaline batteries in the
thermostat. Place the batteries into the battery slot located in the back of the thermostat. Do
not use rechargeable batteries.
Press MENU. Using UP or DOWN, adjust the
temperature and then
press SELECT.
OpenTherm Modulating Control is a method of control used by modern heating systems. Instead of
switching a boiler on and off at intervals, modulating control allows the amount of heat provided by the
boiler to be controlled to match the varying demand from the thermostat. This means the customer has
greater system efficiency, energy saving and room comfort from our heating controls.
Using UP or DOWN, navigate to
Hot Water submenu and
press SELECT.
6
2
7
9
11
17
3A 3B
13
5
4
14
15
16
1
8
10
12
RT520, RT520TX, RT520RF
Quick Guide
6
97
4
10
5
Using UP or DOWN, set the hour
and then press SELECT.
Using UP or DOWN, set the month
and then press SELECT.
Using UP or DOWN, set the
minutes and then press SELECT.
Using UP or DOWN, choose
the time format.
Using UP or DOWN, set the day and
then press SELECT.
Press SELECT to confirm.
1 32
After inserting the batteries, the
thermostat will power up.
Using UP and DOWN, choose your
language and then press SELECT.
Press SELECT.
13 14
Using UP or DOWN, select the
week format.
Press SELECT to confirm. When OpenTherm is connected, the
device software will automatically
adjust to the OpenTherm settings.
8
11
Using UP or DOWN, set the year
and then press SELECT.
Using UP or DOWN, select your
temperature accuracy.
12
Press SELECT to confirm.
54
The text bar indicates that hot
water is in operation.
The thermostat will return to the
main screen. Press any button.
Please make the receiver connections and power the receiver before inserting the batteries
into the thermostat.
Ladda ner bruksanvisning i Engelska (PDF, 5.54 MB)
(Tänk på miljön och skriv endast ut denna bruksanvisning om det verkligen är nödvändigt)

Loading…

Betyg

Berätta vad du tycker om Salus RT 520 Thermostat genom att betygsätta den. Vill du dela med dig av dina åsikter om denna produkt eller ställa en fråga? Lämna en kommentar nederst på sidan.
Är du nöjd med Salus RT 520 Thermostat?
Ja Nej
Bli den första personen som betygsätter denna produkt
0 röster

Delta i konversationen om denna produkt

Här kan du dela vad du tycker om Salus RT 520 Thermostat. Om du har en fråga, läs först noggrant igenom manualen. Att begära en manual kan göras genom att använda vårt kontaktformulär.

Mer om denna bruksanvisning

Vi förstår att det är trevligt att ha en pappersbruksanvisning för din Salus RT 520 Thermostat. Du kan alltid ladda ner bruksanvisningen från vår hemsida och skriva ut den själv. Om du vill ha en originalbruksanvisning rekommenderar vi att du kontaktar Salus. De kanske kan tillhandahålla en originalbruksanvisning. Letar du efter bruksanvisningen för din Salus RT 520 Thermostat på ett annat språk? Välj ditt föredragna språk på vår hemsida och sök efter modellnumret för att se om vi har det tillgängligt.

Specifikationer

Märke Salus
Modell RT 520
Kategori Thermostater
Filtyp PDF
Filstorlek 5.54 MB

Alla bruksanvisningar för Salus Thermostater
Fler bruksanvisningar för Thermostater

Vanliga frågor om Salus RT 520 Thermostat

Vårt supportteam söker efter användbar produktinformation och svar på vanliga frågor. Om du hittar en felaktighet bland våra vanliga frågor uppskattar vi om du meddelar oss detta via vårt kontaktformulär.

Vad är en termostats döda zon? Verifierad

Många moderna termostater har en död zon. Om temperaturen avviker från mindre än 4 ° C från den inställda temperaturen värms eller svalnar systemet inte. Denna så kallade termostats döda zon förhindrar att systemet slås på och av för ofta, vilket sparar energi.

Detta hjälpte (1755) Läs mer

Vad är det bästa stället att montera en termostat på? Verifierad

Det bästa stället för en termostat är cirka 1,5 meter över marken. Placera aldrig termostaten i en radiator eller annan värmeavgivande utrustning eller i direkt solljus. Välj ett rum som används ofta. I de flesta fall är detta vardagsrummet.

Detta hjälpte (1125) Läs mer
Bruksanvisning Salus RT 520 Thermostat

Relaterade produkter

Relaterade kategorier

×
Download