Bruksanvisning Remington TA4570 Rakapparat

Behöver du en bruksanvisning för din Remington TA4570 Rakapparat? Nedan kan du se och ladda ner PDF-bruksanvisningen gratis på svenska. Den här produkten har för närvarande 2 vanliga frågor, 0 kommentarer och har 0 röster. Om det här inte är bruksanvisningen du vill ha, vänligen kontakta oss.

Är produkten defekt och erbjuder bruksanvisningen ingen lösning? Gå till ett Repair Café för gratis reparationstjänster.

Bruksanvisning

Loading…

Every six months, lubricate the trimmer
teeth by applying a drop of light machine oil
one-third and two-thirds of the way along
the blade. Using your finger tip, spread the
oil along the teeth, and run the trimmer for
a few seconds.
Replacing Foils and Cutters
Because they are subject to daily use, the cutters and foils of
your
R e m i n g t o n
®
MicroScreen
®
3 Shaver will wear and eventually
re q u i re replacement to maintain a close, comfortable shave.
Depending on your shaving technique and habits, the foils will
usually last six months; the cutters, one year. Some signs that
your foils and cutters need replacing are :
Irritation. As foils get worn, you may notice your skin feeling
more sensitive after a shave, particularly when you apply after-
shave.
Pulling. As cutters wear, your shave may not feel as close,
and you may feel your shaver is pulling at your whiskers.
Wear-through. You may notice that the cutters have worn
through the foil.
To prevent inadvertent damage to the Foils and Cutter
Assembly, do not attempt to remove them unless you
are replacing them. To remove the old foil and cutters follow
the instructions that come with the foil and cutter replacement
package. It's always a good idea to replace the foils when you
replace the Cutter Assembly.
To Replace a Cutter
Assembly That is Removed
Unintentionally:
Hold the assembly in the middle
of the "T."
Gently place the forked legs into
the opening at the top of the oscilla-
tor tips.
Do not push downward on the ends of the cutters, as you
may bend the cutter, reducing its ability to operate smoothly.
Do not remove cutters from the plastic pieces to which they
are attached, as you may damage the assembly.
Removing the Headguard
Before operating your
MicroScreen
®
3 Shaver, remove the headguard,
which protects the foils and cutter
assembly. It is important to remove
the headguard correctly to avoid
damaging the clips that hold it
firmly to the shaver.
Press lightly on the top of
the headguard.
Lift the lower rear edge.
Pull the headguard away from the shaver.
Cordless Operation
The TA-3070/4570/5570 shavers are designed for
cordless operation and can be recharged easily. For
cordless operation, just press the locking bar in the
center of the On/Off button and push the button
toward the head of the shaver.
Charging
Prior to using your shaver for the first time, put it
on charge for 24 hours. To charge your shaver:
Slide the On/Off button to the “Off” position.
Connect the cord to the shaver and then to the
electric outlet. The charging indicator light will glow
green, indicating your shaver is charging.
The TA-4570 charging indicator will begin to
flash slowly as the shaver reaches full charge.
Your shaver cannot be overc h a rged, so you can
leave it plugged in and charging between shaves.
Use only the cord supplied with shaver. The TA-
3070 is designed for cordless operation only. Plug-
ging in the cord will not provide the power to shave.
The TA-4570/5570 on the other hand, comes with a
special feature that allows you to shave while your
shaver is being recharged. Just follow the steps
above to plug in the cord. Turn on the shaver by
pressing on the locking bar and sliding the On/Off
button upward. Your shaver will not recharge while
you are shaving, so after shaving, leave it plugged in
so it can be recharged.
The TA-4570/5570 will provide a week’s worth of
shaving after a one hour charge or a single shave after
five minutes of charging.
Charging: GREEN LED appears when shaver is plugged in and
charging.
Cordless: When the shaver is operating from the battery in a fully charged
state, the LED will appear GREEN. The LED will gradually change to
AMBER as the battery is depleted. When approximately two shaves
remain, the LED will change from AMBER to RED.
Troubleshooting
If your TA-4570/5570 shaver battery is completely discharged or the
s h a ver has not been used for an extended period of time, the shaver
may not start when operated using the cord. If this condition occurs,
c h a rge the shaver for approximately five minutes before shaving.
Your TA-4570/5570 cord / c o r dless shaver should not be used
strictly as a cord-operated shaver, as continued cord only use will
result in reduction of battery life.
In order to pre s e rve the life of the batteries, they should be fully
d i s c h a rged every six months and then fully charged for 24 hours.
Dual Voltage
You can take your Micro S c re e n
®
3 shaver with you when you travel
just about anywhere in the world. your Micro S c re e n
®
3 shaver
f e a t u res worldwide automatic dual voltage conversion providing AC
c u r rent between 100-240 volts, 50-60 Hz. Just plug it in to the local
outlet (you may need an adapter plug) and use as usual. Your shaver
will convert automatically to the local current re q u i re m e n t s .
The following procedures should
be followed for battery removal:
Make sure your shaver is unplugged from
any outlets,so you don't risk an electrical
shock.
Remove the head assembly by gently lifting
the assembly away from the shaver.
Using a small Phillips head screwdriver, remove the four screws
from the upper and lower back of the shaver.
Pull or gently pry the shaver halves apart,exposing the battery.
Lift the rubber Side Panels from their cradles and put
them aside.
Hold each battery in place and very carefully slide the clips
from the terminals on each battery.
Lift or pry the battery out of the shaver.
CAUTION:THESE NICKEL-CADMIUM BATTERIES MUST BE RECY-
CLED OR DISPOSED IN ACCORDANCE WITH STATE AND LOCAL
REGULATIONS.Do not burn or mutilate,as they may burst or
release toxic materials.Do not short-circuit,as it may cause burns.
Ladda ner bruksanvisning i Engelska (PDF, 0.17 MB)
(Tänk på miljön och skriv endast ut denna bruksanvisning om det verkligen är nödvändigt)

Loading…

Betyg

Berätta vad du tycker om Remington TA4570 Rakapparat genom att betygsätta den. Vill du dela med dig av dina åsikter om denna produkt eller ställa en fråga? Lämna en kommentar nederst på sidan.
Är du nöjd med Remington TA4570 Rakapparat?
Ja Nej
Bli den första personen som betygsätter denna produkt
0 röster

Delta i konversationen om denna produkt

Här kan du dela vad du tycker om Remington TA4570 Rakapparat. Om du har en fråga, läs först noggrant igenom manualen. Att begära en manual kan göras genom att använda vårt kontaktformulär.

Mer om denna bruksanvisning

Vi förstår att det är trevligt att ha en pappersbruksanvisning för din Remington TA4570 Rakapparat. Du kan alltid ladda ner bruksanvisningen från vår hemsida och skriva ut den själv. Om du vill ha en originalbruksanvisning rekommenderar vi att du kontaktar Remington. De kanske kan tillhandahålla en originalbruksanvisning. Letar du efter bruksanvisningen för din Remington TA4570 Rakapparat på ett annat språk? Välj ditt föredragna språk på vår hemsida och sök efter modellnumret för att se om vi har det tillgängligt.

Specifikationer

Märke Remington
Modell TA4570
Kategori Rakapparater
Filtyp PDF
Filstorlek 0.17 MB

Alla bruksanvisningar för Remington Rakapparater
Fler bruksanvisningar för Rakapparater

Vanliga frågor om Remington TA4570 Rakapparat

Vårt supportteam söker efter användbar produktinformation och svar på vanliga frågor. Om du hittar en felaktighet bland våra vanliga frågor uppskattar vi om du meddelar oss detta via vårt kontaktformulär.

I vilken riktning ska jag raka mig? Verifierad

I de flesta fall rekommenderas att du rakar med hårväxtens riktning. Detta minskar risken för irriterad hud och inåtväxt hår.

Detta hjälpte (205) Läs mer

Vad är skillnaden mellan vibrerande och roterande rakhuvuden? Verifierad

Detta handlar mest om personliga behov och preferenser, men i allmänhet kan man säga att knivarna i vibrerande rakhuvuden rör sig snabbare och därför ger snabbare resultat. Ett roterande rakhuvud kan lättare nå vissa delar av ansiktet.

Detta hjälpte (187) Läs mer
Bruksanvisning Remington TA4570 Rakapparat

Relaterade produkter

Relaterade kategorier

×
Download