Behöver du en bruksanvisning för din Hozelock 1760 EasyClear 3000 Fontänpump? Nedan kan du se och ladda ner PDF-bruksanvisningen gratis på svenska. Den här produkten har för närvarande 0 vanliga frågor, 0 kommentarer och har 0 röster. Om det här inte är bruksanvisningen du vill ha, vänligen kontakta oss.

Är produkten defekt och erbjuder bruksanvisningen ingen lösning? Gå till ett Repair Café för gratis reparationstjänster.

Bruksanvisning

Loading…

according to local regulations and fit the new
lamp.
4 - Slide the quartz tube down over the lamp. Ensure
that the two o-rings at the base of the quartz tube
are clean and free from debris.
5 - Slide the locking collar down over the quartz tube

the stop of the locking collar hits the stop of the
housing so that the collar cannot be screwed
down any more.
6 - Reassemble the bayonet tube and screw and
restart (Fig 8-S).
Warning! Ensure that the quartz tube is assembled
correctly so that it provides a completely watertight
seal.
Check the condition of the two o-rings on the Quartz
Tube Assembly (Fig 9-T-iii). If these are damaged in
any way or you cannot guarantee a water tight seal,
contact Hozelock Consumer Services.
Biological Filter
Normally, there is no need to remove the biomedia
as any cleaning may kill the colonies of bacteria that
make toxic waste harmless. However if the biomedia
becomes heavily clogged and does require cleaning
follow this procedure.
1 - Remove the foam.
2 - The bag of Kaldnes Biomedia (Fig 7-P) can then be
removed for cleaning.
3 - Wash in pond water.
4 - Reassemble the filter and restart.
Rotor Cleaning/Replacement
If the no water is being pumped or flow is reduced,
remove the quartz tube and lamp as described above,
then follow the below procedure.
1 - Release the Foam Cover by pushing the two
buttons (Fig 5-M) and lift the cover (Fig 6-N).
2 - Remove the foam (Fig 7-O), biomedia (Fig 7-P)
and stone bag.
3 - Turn the unit over and remove the 4 fixing screws
(Fig 10-V) and lift the base clear.
4 - Remove the 2 fixing screws (Fig 10-W) and lift the
Pump Assembly clear.
5 - Twist the Pump Chamber anticlockwise (Fig 10-X)
and lift clear. The rotor can now be pulled out

Important! Take extra care so as to not drop
any of the small components. See Fig 10A for
assembly of the rotor.
6 - Reassemble the pump and 2 off fixing screws (Fig
10-W).
7 - Reroute the cable (Fig 10-Z).
8 - Reassemble the filter, and restart.

A quick daily check should be carried out to ensure
that the pump is performing satisfactorily.
Once a week- Remove the outer casing and Fountain
Head in accordance with the general maintenance
notes.
Depending on pond water conditions, cleaning may be
required more frequently.
Once a year- Completely disassemble the unit
including the Rotor Assembly as described in the
general maintenance notes, and wash all components
in clean, freshwater.
Replace worn or broken parts.
Winter Storage
When not in use, the unit should be removed,
thoroughly washed and cleaned, dried and stored in
a dry frost protected area. Always store the unit with
the foam and foam cover off to ensure adequate
ventilation anddrying.

For product advice and spares please contact
Hozelock Cyprio Consumer Services on 0121 313 1122
or visit www.hozelock.com
Fish Stocking and Density
Under normal conditions, the EasyClear™ 3000 or
4500 will support up to 72cm of fish. Introduce fish
slowly over the first few weeks, up to 20% of the
maximum recommended level, increasing to 50% after
six months. The balance will allow for fish growth.
Hozelock Cyprio Clearwater Guarantee
WE GUARANTEE YOU CLEAR WATER OR YOUR
MONEY BACK.
NOTE: IN SOME CASES IT CAN TAKE UP TO 6-8
WEEKS FOR YOUR WATER TO BECOME CLEAR.
This guarantee runs for 12 months after purchase,
provided that

instructions.

stocking level.

enough for any problems to be put right.

A refund can only be authorised by Hozelock Cyprio
and is made only at the place of purchase to the
value of the purchase price of the EasyClear™ only.
A Proof of Purchase will be required.Please note that
the Clearwater Guarantee does not cover loss of water
clarity when blanketweed, as opposed to greenwater
algae, is the cause.
Ladda ner bruksanvisning i Svenska (PDF, 1.3 MB)
(Tänk på miljön och skriv endast ut denna bruksanvisning om det verkligen är nödvändigt)

Loading…

Betyg

Berätta vad du tycker om Hozelock 1760 EasyClear 3000 Fontänpump genom att betygsätta den. Vill du dela med dig av dina åsikter om denna produkt eller ställa en fråga? Lämna en kommentar nederst på sidan.
Är du nöjd med Hozelock 1760 EasyClear 3000 Fontänpump?
Ja Nej
Bli den första personen som betygsätter denna produkt
0 röster

Delta i konversationen om denna produkt

Här kan du dela vad du tycker om Hozelock 1760 EasyClear 3000 Fontänpump. Om du har en fråga, läs först noggrant igenom manualen. Att begära en manual kan göras genom att använda vårt kontaktformulär.

Mer om denna bruksanvisning

Vi förstår att det är trevligt att ha en pappersbruksanvisning för din Hozelock 1760 EasyClear 3000 Fontänpump. Du kan alltid ladda ner bruksanvisningen från vår hemsida och skriva ut den själv. Om du vill ha en originalbruksanvisning rekommenderar vi att du kontaktar Hozelock. De kanske kan tillhandahålla en originalbruksanvisning. Letar du efter bruksanvisningen för din Hozelock 1760 EasyClear 3000 Fontänpump på ett annat språk? Välj ditt föredragna språk på vår hemsida och sök efter modellnumret för att se om vi har det tillgängligt.

Specifikationer

Märke Hozelock
Modell 1760 EasyClear 3000
Kategori Fontänpumpar
Filtyp PDF
Filstorlek 1.3 MB

Alla bruksanvisningar för Hozelock Fontänpumpar
Fler bruksanvisningar för Fontänpumpar

Bruksanvisning Hozelock 1760 EasyClear 3000 Fontänpump

Relaterade produkter

Relaterade kategorier